Pantera® Pro
Indicated for dilatation of coronary artery or bypass graft stenosis.a
Product Highlights
Better Crossability²
Slim shoulders coupled with hydrophilic coatingb facilitate better crossing2
43% less friction³ during simultaneous use
Reduced distal shaft diameter for improved 6F simultaneous use compatibilityc1
38% more pushability⁴
Enhanced Force Transmission (EFT) shaft for unmatched pushability1
Technical Data
Proximal shaft | |
---|---|
Design | Hypotube design |
Diameter | 2.0F |
Shaft markers | 92 cm and 102 cm from tip |
Distal shaft | |
Guiding catheter | 5F (min. I.D. 0.056” / 1.42 mm) |
Guide wire diameter | 0.014” |
Lesion entry profile | 0.017” |
Usable length | 140 cm |
Balloon material | Semi Crystalline Co-Polymer |
Balloon folding | ø 1.25 - 1.5 mm: Two-fold; ø 2.0 - 4.0 mm: Tri-fold |
Balloon markers | Platinum-Iridium: ø 1.25 - 1.5 mm one marker; ø 2.0 - 4.0 mm two markers |
Coating distal shaft | Hydrophilic (end of balloon to Guide Wire (GW) exit port) |
Balloon and tip coating | ø 1.25 - 2.0 mm: Hydrophilic ø 2.50 - 4.0 mm: Hydrophobic |
Simultaneous use compatibility | 6F guiding catheter (min. I.D. 0.070” / 1.78 mm), up to ø 3.5 mm |
Diameter | 2.6F (ø 1.25 - 2.0 mm); 2.7F (ø 2.5 - 3.5 mm); 2.9F (ø 4.0 mm) |
Compliance Chart
Balloon diameter x length (mm) | ||||||||
---|---|---|---|---|---|---|---|---|
ø 1.25 x 6-20 |
ø 1.50 x 6-20 |
ø 2.00 x 10-30 |
ø 2.50 x 10-30 |
ø 3.00 x 10-30 |
ø 3.50 x 10-30 |
ø 4.00 x 10-30 |
||
Nominal Pressure (NP) |
atm* | 7 | 7 | 7 | 7 | 7 | 7 | 7 |
ø (mm) |
1.24 |
1.49 |
2.01 |
2.49 |
3.08 |
3.62 |
3.95 |
|
Rated Burst Pressure (RBP) |
atm* | 14 | 14 | 14 | 14 | 14 | 14 | 14 |
ø (mm) |
1.37 |
1.72 |
2.23 |
2.93 |
3.50 |
4.06 |
4.55 |
|
*1 atm = 1.013 bar |
Ordering Information
Balloon ø (mm) |
Catheter length 140 cm Balloon length (mm) |
||||||
---|---|---|---|---|---|---|---|
6 | 10 | 15 | 20 | 25 | 30 | ||
5F | 1.25 | 393289 | 393291 | 393298 | 393305 | - | - |
1.50 | 393290 | 393292 | 393299 | 393306 | - | - | |
2.00 | - | 393293 | 393300 | 393307 | 393312 | 393317 | |
2.50 | - | 393294 | 393301 | 393308 | 393313 | 393318 | |
3.00 | - | 393295 | 393302 | 393309 | 393314 | 393319 | |
3.50 | - | 393296 | 393303 | 393310 | 393315 | 393320 | |
4.00 | - | 393297 | 393304 | 393311 | 393316 | 393321 |
Downloads and Related Links
Downloads
Related Links
How can we help you?
References
a. Indication as per IFU; b. 1.25-2.0 mm diameter; c. Any combination of two diameters not larger than 3.5 mm within a 6F guiding catheter with a minimal inner diameter of 0.070”/1.78 mm.
1. BIOTRONIK data on file; 2. Bench test with 1.5/15mm size when compared to Mini Trek and Emerge, BIOTRONIK data on file; 3. Bench test with 3.0/20mm size when compared to Trek, BIOTRONIK data on file; 4. Bench test with 1.5/15mm size when compared to Mini Trek, BIOTRONIK data on file.
Pantera is a trademark or registered trademark of the BIOTRONIK Group of Companies.