Maintain perfusion* during deep intubation.¹
- 9 circumferential perfusion holes to maintain optimal perfusion* of distal vessel and side branches.1
- Reduce the risk of pressure damping and procedure induced ischemia.1
Reduce the risk of pressure damping and procedure induced ischemia1. FlowGuide has 9 circumferential perfusion holes to maintain blood flow* to distal vessel and side branches. Its 15 cm distal shaft is designed to optimize trans-radial approach.1
Guide extension catheter | |
---|---|
Distal shaft length | 15 cm |
Shaft material | Polyether Block Amide |
Tip | Flexible Radiopaque Atraumatic, 1.3 mm length |
Outer coating | Hydrophilic, distal 12 cm |
Exit markers | 95 cm and 105 cm |
Usable length | 150 cm |
BIOTRONIK/IMDS Portfolio | ||||||||
---|---|---|---|---|---|---|---|---|
Navigate | Prepare | Treat | ||||||
FlowGuide | ReCross2 | NHancer Rx2 | Pantera LEO2 | Pantera Pro2 | Orsiro Mission2 | Pantera Lux2 | Freesolve3 | PK Papyrus2 |
6F | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | - | ✔(2.5-4.0) |
Other Devices | |||||||
---|---|---|---|---|---|---|---|
IVUS | Single Lumen Microcatheters | Rotablator Burr | IVL | ||||
FlowGuide | Eagle Eye Platinum Family, Refinity ST4 |
ACIST KODAMA3 |
Low Profile OD Microcatheters (<3F)5 |
Large Profile OD Microcatheters (Twin-Pass 3.4F)5 |
1.25 mm6 & 1.5 mm6 |
Shockwave C27 |
Shockwave C2+8 |
6F | ✔ | - | ✔ | ✔ | - | ✔ | ✔ |
Name | Ordering Number | IMDS article Number | Required guide catheter ID | Inner Diameter | Perfusion Holes |
---|---|---|---|---|---|
FLOWGUIDE | 490395 | FG60F | 6F, ID ≥ 0.070" (1.78 mm) | 0.056" (1.42 mm) | 9 |
GUIDION SHORT | 490394 | GS60F | 6F, ID ≥ 0.070" (1.78 mm) | 0.056" (1.42 mm) | 0 |
Guidion Short = guide extension catheter for CTO PCI which has the same design as FlowGuide, with the exclusion of the perfusion holes and different end-stop color (yellow).
*Optimal perfusion performance dependent on the relative position of the perfusion holes; **Please refer to the Instruction for Use.
1. IMDS data on file. 2. According to the comparison between minimum dimension of Guiding catheter of the device in the IFU and the labeled inner diameter of FlowGuide. 3. According to IFU. 4. According to the comparison between the requirement for Guiding Catheters (≥0.056"/1.42 mm – Eagle Eye Platinum, Refinity ST and Eagle Eye Platinum ST, Philips IVUS Spec sheet Feb 2024) and the labeled inner diameter of FlowGuide. 5. Garbo R. et al. JACC Cardiovasc Interv. 2023 Aug 14;16(15):1833-1844. doi: 10.1016/j.jcin.2023.05.019. PMID: 37587590. 6. Pawłowski T. et al. Postepy Kardiol Interwencyjnej. 2021 Jun;17(2):210-213. doi: 10.5114/aic.2021.107502. Epub 2021 Jul 9. PMID: 34400924; PMCID: PMC8356840. 7. Based on C2 - PN 62185 Rev F - Shockwave C2 Coronary IVL Catheter IFU, US.pdf downloaded on Feb 7, 2024. 8. Based on PN 64192 Rev C – IFU, Shockwave C2+ Coronary IVL Catheter, US.pdf downloaded on Feb 7, 2024. The compatibility conclusions provided in this document are based on general & public information. It is advised to consult the manufacturer of each device for precise compatibility details.
FlowGuide and Guidion Short are trademarks of IMDS. Manufactured by IMDS and distributed by BIOTRONIK in selected countries.