MR CONDITIONAL CRT-P

Compared to its predecessor, Edora’s reduced form factor has no negative effects on its battery, still boasting an impressive 13 years1 of longevity in the single-chamber variant. Consistent with BIOTRONIK’s long-standing MRI leadership, Edora offers MRI AutoDetect, a revolutionary feature that is designed to improve efficiency for providers by eliminating the post-scan reprogramming requirement. It also aims to improve the patient experience by reducing the length of time the device is in MRI mode and the added benefit of flexibility in scheduling. 

 

Category

CRT-P

Product Highlights

Image
Quadripolar LV Pacing

Quadripolar LV Pacing

Enables multiple left-ventricular pacing and sensing configurations for CRT management

Image
LV VectorOpt

LV VectorOpt including RV-LV Conduction Time Measurement

Simplifies the process to select the right pacing vector

Image
MRI AutoDetect

MRI AutoDetect

Simplifies MRI access by automatically detecting an MR environment and switching the system to safe MRI mode, programmable for up to 14 days

Product Details

  • ProMRI®2: Allows patients to undergo MRI scanning under specific conditions. Also allows for LV pacing during MRI mode.
  • MRI AutoDetect: Simplifies workflows through automatic detection of MRI environment and minimizes patients' time in MRI mode.
  • BIOTRONIK Home Monitoring®: Effective remote monitoring of heart failure and system integrity based on automatic and wireless daily transmissions. Remote follow-up device interrogation allows earlier intervention as approved by the FDA.
  • Closed Loop Stimulation (CLS): Unique physiological rate response modulation during episodes of physical and acute mental stress. CLS is the only pacemaker algorithm that responds to physiologic demands and acute mental stress on a beat-to-beat basis.
  • Quadripolar LV Pacing: Enables multiple left-ventricular pacing and sensing configurations for CRT management.
  • LV VectorOpt: User-friendly interface for LV lead testing, simplifying the selection of the optimal pacing vector.
  • Event-triggered wireless IEGM transmissions within 24 hours: Enables prompt evaluations for fast and better informed therapy decisions.
  • Capture Control (RA, RV & LV): Automatic adjustment of pacing amplitudes for effective CRT therapy.
  • AV Opt: Facilitates programming of optimal AV timing.
  • SafeSync RF Telemetry: RF telemetry for wandless, time-saving and reliable data transmission at implantation and follow-up.

Media

Video
MRI AutoDetect
Video
Closed Loop Stimulation

Contact Us

I prefer to be contacted by
*Fields are mandatory.

References

1) Edora SR, 10 cc volume; 2. AAI(R) @ 2.5 V, 0.4 ms, 60 ppm, 100% pacing, 500 Ω, RF-Telemetry off. 2) For combination of MR conditional devices, please see the "ProMRI® MR conditional device systems" manual